Running Businesses for Sale, Consultancy for new business setup: Call Now03219251379 / 03009251379 / 03349251379

Expert Consultancy and Licensing Services for Dangerous Chemicals and Petroleum Products in Pakistan

Expert Consultancy and Licensing Services for Dangerous Chemicals and Petroleum Products in Pakistan

Expert Consultancy and Licensing Services for Dangerous Chemicals and Petroleum Products in Pakistan

At M/s. Excellent Services, we provide consultancy services for the storage of Dangerous Chemicals, Petroleum Products, and Chemicals. We understand that obtaining a license for the storage of these materials can be a complicated and lengthy process. Therefore, we assist our clients in obtaining all the necessary NOCs from different departments like D.C.O, T.M.O, Civil Defence, Anti-Narcotic Force, Environment and Protection Agency, DIG, etc., as well as proposing a plan for the storage of chemicals.

We also assist in obtaining the required forms for various types of licenses:

Form of License Purpose of Grant
Form “K” For Petrol Pumps for Storage of Petrol, Diesel & Lube Oil
Form “L” For Individuals and Oil Companies for Storage of Petroleum Products and Chemicals in bulk storage above-ground or in underground tanks.
Form “M” For Individuals and Oil Companies for Storage of Petroleum Products and Chemicals in non-bulk storage in storage godowns.
Form “B-1” For CNG Stations
Form “N” For LPG Stations
Form “O” For LPG to fill Cylinders
Form “Q” For Transportation of Petroleum Products by land/road
Form “C” For Import and Storage of Carbide of Calcium
Form “Spl” For storage and sale of petroleum products by ship/barge.

We specialize in arranging licenses for storage of 0 to 30,000 gallons of dangerous chemical storage and dangerous petroleum items in Pakistan. Our team of experts can help you meet all the requirements for obtaining the necessary NOCs, proposing a plan for storage, and preparing the required documents for the grant of license for non-bulk storage godown.

It is crucial to meet specific requirements for the construction of a storage godown. Therefore, we ensure that the materials used in construction are C.C. Block Wall, RCC Column, and no wood is used in the construction of storage godowns. Additionally, the floor of the storage godown is 2’-0” deep/sump, and ventilators are provided 6” above ground level and at 1’ below the roof, covered with single copper wire gauge mesh of 28 linear inches.

Furthermore, the door of the storage shed is of Angel Iron form of G.I Sheet and open drawing. We provide firefighting arrangements as required under Petroleum Rules, 1937. Smoking is not allowed inside the premises, and there is no use of fire/burner inside the guard/incharge room for cooking or any other purpose. At least one guard will be provided round the clock, fully conversant with the fire-fighting techniques. The existing industrial shed does not contain any dangerous petroleum goods, and offices are completely closed/empty without any activity.

Overall, M/s. Excellent Services is your one-stop solution for obtaining consultancy for dangerous chemicals, petroleum products, and chemical storage licenses. We ensure that you meet all the requirements for obtaining a license and can guide you through the entire process, making it hassle-free and time-efficient.

Dangerous Petroleum License [DPL]

  1. ACETONE
  2. AERYONITHRIL
  3. ALUMINIUM POWDER
  4. AMMONIUM NITRATE
  5. ANTIMONY SULPHIDE
  6. ARSENIC SULPHIDES
  7. BENZENE
  8. BENZOL
  9. BUTANE (N.Butyl)
  10. BENZENE NAPTIIAL
  11. CHARCOAL
  12. COTTON WOOL
  13. CALCIUM CARBIDE
  14. COAL TAR NAPHTHA
  15. DIACETONE ALCOHOL
  16. DECAHYDRO NAPHTHALAMIN
  17. ETHYL ALCOHOL
  18. GLYCERINE
  19. ISO-OCTANE
  20. METHYL ALCOHOL
  21. METHANOL
  22. METHYL METHACRYLATE MONOMER
  23. MERCURY
  24. NITRIC ACID
  25. POTASSIUM NITRATE
  26. POTASSIUM CHLORIDE
  27. PRINTING INK
  28. PHOSPHOROUS
  29. PETROLEUM ETHER
  30. PATROLLING
  31. PETROL SPIRIT
  32. CITRIC ACID
  33. CTLFIF SPIRIT
  34. SOLVENT NAPHTHA LIGHT
  35. SOLVENT NAPHTHA HEAVY
  36. SODIUM NITRATE
  37. SULPHUR
  38. SULPHURIC ACID
  39. TOLUOL
  40. THINNER
  41. TOLUENE
  42. VINYL ACETATE
  43. WOOD NAPHTHA
  44. WHITE SPIRIT
  45. XYLENE META
  46. XYLOLS
  47. METHYL ETHYL KETONE (BUTANONE)
  48. ISOPROPYL ALCOHOL (IPA)

Requirements for license

NOC from different departments like D.C.O, T.M.O, Civil Defence
Anti Narcotic Force, Environment and Protection Agency, DIG, etc…..proposed a plan for
Storage of chemicals.

The Department of Explosives will need the following documents for the grant of license for non-bulk storage godown:

– Application Form “D” duly filled in and signed by the Owner
– Treasury challan deposited in federal treasury as per quantity.
– NOC from the District Authority with a site/location plan duly
attested by him and SITE Association
– Land ownership documents
– If the land is acquired from the land-lord/lady then a Tenancy Agreement
duly registered with Registrar.
– Proposed plan 5 copies.


NOTES / CERTIFICATE
1.    MATERIAL USED IN CONSTRUCTION OF C.C. BLOCK WALL, RCC COLUMN, NO WOOD IS USED IN CONSTRUCTION OF STORAGE GODOWN.
2.    THE FLOOR OF THE STORAGE GODOWN BE 2’-0” DEEP/SUMP.
3.    VENTILATORS WILL BE PROVIDED 6” ABOVE GROUND LEVEL AND AT 1’ BELOW THE ROOF, COVERED WITH SINGLE COPPER WIRE GAUGE MESH OF 28 LINEAR INCHES. AS SHOWN IN THIS DRAWING.
4.    THE DOOR OF THE STORAGE SHED WILL BE OF ANGEL IRON FROM OF G.I SHEET AND OPEN DRAWING.
5. FIREFIGHTING ARRANGEMENTS WILL BE MADE AS REQUIRED UNDER PETROLEUM RULES, 1937.
6.    NO NATURAL GAS MAIN EXISTS WITHIN A 50’ RADIUS.
7.    SMOKING WILL NOT BE ALLOWED INSIDE THE PREMISES.
8.    THERE WILL BE NO USE OF A FIRE/BURNER INSIDE THE GUARD/INCHARGE ROOM FOR COOKING OR ANY OTHER PURPOSE.
9.    AT LEAST ONE GUARD WILL BE PROVIDED ROUND THE CLOCK, FULLY CONVERSANT WITH THE FIRE-FIGHTING TECHNIQUES.
10.    THE EXISTING INDUSTRIAL SHED DOES NOT CONTAIN ANY DANGEROUS PETROLEUM GOODS AND OFFICES ARE COMPLETELY CLOSED/EMPTY WITHOUT ANY ACTIVITY.